Instruction Manual SVS1 Series
55
The ROI now has to be suitably resized and positioned: follow the instructions provided earlier
during this procedure.
We access the Adjust mode by pressing the STATUS button. Let's increase the minimum edge
limit value to 3 using the ARROW UP button.
Use the RIGHT ARROW button to set the type of variation to be detected. Use the ARROW UP
button to see the Black to White value.
Now press the STATUS button to enter Monitor Mode and check that the tool functions properly.
The sensor now behaves correctly. As the result is satisfying, press STATUS again and move on
to defining the behaviour of the outputs.