FUNCTION
CANCEL
ENTER
INSTRUCTION MANUAL
Handy Controller Exclusive for SE4D Series
SE9Z-HC
B-1430(0)
MJE-SE9ZHC No.0027-96V
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

FUNCTION-CANCELENTER+INSTRUCTION MANUALHandy Controller Exclusive for SE4D Series SE9Z-HCB-1430(0)MJE-SE9ZHC No.0027-96V

Pagina 2

9Functional Descriptions3-1-2 Floating Blanking FunctionThis function is set in each SE4D series.If the number of the blocked beam channels is less t

Pagina 3

10Functional Descriptions<Minimum sensing object>Floating blanking functionIneffectiveEffective1 beam channel 2 beam channels 3 beam channelsSE4

Pagina 4 - Contents

11Functional Descriptions3-1-4 Emission Intensity Control FunctionThis function reduces the emitting intensity.It is useful for preventing interferen

Pagina 5 - CHAPTER 1 INTRODUCTION

12Functional DescriptionsMuting input conditions ● The order for inputting the muting input A and B, which the muting function activates, can be set.A

Pagina 6 - INTRODUCTION

13Functional Descriptions3-1-9 Protective FunctionThe functional settings are not allowed to change without the input of a password.When the protecti

Pagina 7 - CHAPTER 2 GENERAL OUTLINE

14Function Setting3-2 Function Setting (Operation Procedure)This section describes the setting of each function (operation procedure).<Selecting t

Pagina 8

15Function Setting<Inputting a password>When the protective function is effective, “Lock” is shown on the lower section of the digital display.

Pagina 9 - CHAPTER 3 FUNCTIONS

16<Selecting sensor>Each function can be set on each SE4D series connected in series as well. Select a SE4D series to set each function.RemarksS

Pagina 10 - Functional Descriptions

17Function Setting3-2-1 Fixed Blanking Function(Sub sesnor 2)1. Fixed blankingfunction2. To Floating blanking functionSelect function(Ineffect

Pagina 11

18Function Setting3-2-2 Floating Blanking FunctionFLO1 <Effective setting of beam channel>0: Ineffective1: 1 beam channel setting2: 2 beam chan

Pagina 12

1(MEMO)

Pagina 13

19Function Setting3-2-3 Auxiliary Output Switching Function*: When two or more SE4D series are connected, cancel the protective function of all SE4D

Pagina 14

20Function Setting3-2-4 Emission Intensity Control Function<Emission intensity control>CLR (Ineffective) : Operating range is 0.3 to 9m for SE4

Pagina 15 - Function Setting

21Function Setting3-2-5 Copy Function“****” indicates the connection state of the system. ● “ ”: Used when connected to the SE4D series.*1: The set

Pagina 16

22Function Setting3-2-6 Muting Setting Changing FunctionTo 6(Error)OKNGSelect “send” (NONO)(NONC)Muting sensor output operation settingMuting sensor

Pagina 17

23Function Setting*: The functional setting of each beam channel is as follows.on : The muting function is effective.oFF : The muting function is in

Pagina 18

24Function Setting3-2-7 Interlock Setting Changing Function*: When two or more SE4D series are connected, cancel the protective function of all SE4D

Pagina 19

25Function Setting3-2-8 External Device Monitor Setting Changing Function*: When two or more SE4D series are connected, cancel the protective functi

Pagina 20

26Function Setting3-2-9 Protective FunctionSend(Error)To 9OKNGSend(Error)To 9OKNG(All sensors)(Main sensor)10. To Sub dis- play function /

Pagina 21

27Function Setting3-2-10 Initialization Function(All sensors)(Main sensor)11. To Sub dis- play function / Setting con- tents moni-

Pagina 22

28Function Setting3-2-11 Setting Contents Monitoring Function(NONO)Muting sensoroutput operationsetting*:60 to 600 (unit of 10)(Note)Override setting

Pagina 23

2Thank you for purchasing IDEC’s Handy Controller SE9Z-HC exclusive for SE4D series.Please read both the instruction manual of this manual and SE4D se

Pagina 24

29Function Setting3-2-12 Override Setting Changing FunctionSend(Error)To 12OKNGTime setting(60 sec.)(70 sec.)(80 sec.)(600 sec.)9. To Sub display

Pagina 25

30CHAPTER 4 TROUBLESHOOTINGSymptoms Cause RemedyControl output (OSSD 1 / 2) is not turned ON.This device is connected to the SE4D series.Disco

Pagina 26

31CHAPTER 5 SPECIFICATIONS / DIMENSIONS5-1 SpecicationsModel No.ItemSE9Z-HCApplicable model Light curtain SE4D seriesSupply voltage 24V DC±10% Rip

Pagina 27

32Revision historyFirst edition January 10, 2012

Pagina 28

33(MEMO)

Pagina 29

1. CAUTIONS FOR SAFE USE(1) The applications shown in the catalogue are only suggestions, and it is Purchaser's sole responsibility to ascert

Pagina 30

2012.2http://www.idec.com7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, JapanWendenstrasse 331, D-20537, Hamburg, GermanyIDEC ELEKTROTECHN

Pagina 31 - CHAPTER 4 TROUBLESHOOTING

3ContentsCHAPTER 1 INTRODUCTION ...41-1 Attention Marks ...

Pagina 32 - 5-2 Dimensions

4CHAPTER 1 INTRODUCTION1-1 Attention MarksThis instruction manual employs the following attention marks , depending on the degree of the dang

Pagina 33 - Revision history

5 ♦ Fixed blanking function, oating blanking function ● With the xed blanking function, this device prevents the person or object from entering into

Pagina 34

6CHAPTER 2 GENERAL OUTLINEThis chapter gives the system construction, part description, etc. of this device.2-1 FeaturesThis device is the handy

Pagina 35

7Connecting / Setting Procedures2-3 Connecting / Setting ProceduresThis section describes the connecting / setting procedures for both this device an

Pagina 36 - IDEC ELEKTROTECHNIK GmbH

8CHAPTER 3 FUNCTIONSIf conguration of the system is changed (replace the SE4D series etc.), set the function again.3-1-1 Fixed Blanking FunctionThi

Comentarios a estos manuales