Idec FL1E SmartRelay Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Idec FL1E SmartRelay. IDEC FL1E SmartRelay User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 356
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 2 - Revision History

viii IDEC SmartRelay Manual3.5 Overview of IDEC SmartRelay menus ... 683.6 Writing and starting the circuit pr

Pagina 3

I:0.. 1234567891..01234567892..01234L1NV4 V5=1L4L5T4Q:0.. 1234567891..0123456Let us examine this using our example:When switch S1 is closed, the statu

Pagina 4

Programming IDEC SmartRelay IDEC SmartRelay Manual 87This is the circuit program layout in IDEC SmartRelay:1Q1I1I2xxParThis is the new blockYou can se

Pagina 5 - IDEC SmartRelay Manual iii

Programming IDEC SmartRelay 88 IDEC SmartRelay ManualPress to select the SF list:Q1SFThe SF list contains the special function blocks.Press OK.The

Pagina 6

Programming IDEC SmartRelay IDEC SmartRelay Manual 89Assigning block parameters Now you set the off-delay time T:1. Move the cursor to Par, if it not

Pagina 7 - IDEC SmartRelay Manual v

Programming IDEC SmartRelay 90 IDEC SmartRelay ManualSetting the timeSet the time T = 12:00 minutes:1. Move the cursor to the first digit: Press or

Pagina 8

Programming IDEC SmartRelay IDEC SmartRelay Manual 91NoteFor further information on the protection mode, refer to Chapter 4.3.5.For further informatio

Pagina 9 - Contents

Programming IDEC SmartRelay 92 IDEC SmartRelay Manual3.6.8 Deleting a blockLet us assume you want to delete the block B2 from your circuit program an

Pagina 10

Programming IDEC SmartRelay IDEC SmartRelay Manual 933.6.9 Deleting block groupsLet us assume you want to delete the blocks B1 and B2 from the followi

Pagina 11 - IDEC SmartRelay Manual ix

Programming IDEC SmartRelay 94 IDEC SmartRelay Manual3.6.10 Correcting programming errorsProgramming errors can be corrected easily in IDEC SmartRela

Pagina 12

Programming IDEC SmartRelay IDEC SmartRelay Manual 95Defining a specific analog output valueTo output a specific analog value at the two analog output

Pagina 13 - IDEC SmartRelay Manual xi

IDEC SmartRelay Manual ix4.3.3 Backup of the real-time clock ... 1234.3.4 Retentivity...

Pagina 14

Programming IDEC SmartRelay 96 IDEC SmartRelay Manual3.6.13 Deleting the circuit program and passwordTo delete a circuit program and the password if

Pagina 15 - SmartRelay

Programming IDEC SmartRelay IDEC SmartRelay Manual 977. Enter your password.8. Press OK. The circuit program and the password are deleted.NoteIn case

Pagina 16 - 2 IDEC SmartRelay Manual

Programming IDEC SmartRelay 98 IDEC SmartRelay ManualTo enable/disable automatic S/W Time conversion in parameter assignment mode:If you want to enab

Pagina 17 - IDEC SmartRelay Manual 3

Programming IDEC SmartRelay IDEC SmartRelay Manual 99The table below lists the preset conversions:NoteYou can specify a time zone difference  between

Pagina 18

Programming IDEC SmartRelay 100 IDEC SmartRelay ManualUser-defined parametersIf none of the parameters/conversions apply to your country, you can cus

Pagina 19 - (example: 

Programming IDEC SmartRelay IDEC SmartRelay Manual 101NoteTo disable summertime/wintertime conversion in this menu, you merely confirm ‘Off’ with OK.N

Pagina 20 - Version number

Programming IDEC SmartRelay 102 IDEC SmartRelay ManualEnabling synchronization You want to enable synchronization:1. Move the ‘>’ cursor to ‘On’:P

Pagina 21 - FL1D-K2B2

Programming IDEC SmartRelay IDEC SmartRelay Manual 1033.7 Memory space and circuit program sizeThe size of a circuit program in IDEC SmartRelay is li

Pagina 22 - FL1D-K2BM2

Programming IDEC SmartRelay 104 IDEC SmartRelay Manual!CautionAt a power failure, the logical input level may drop to zero before IDEC SmartRelay can

Pagina 23 - IDEC SmartRelay Manual 9

Programming IDEC SmartRelay IDEC SmartRelay Manual 105Resources available in IDEC SmartRelayA circuit program in IDEC SmartRelay can occupy the follow

Pagina 24 - 10 IDEC SmartRelay Manual

x IDEC SmartRelay Manual4.4.30 Analog math ... 2254.4.31 Analog math err

Pagina 25

Programming IDEC SmartRelay 106 IDEC SmartRelay Manual*: Bytes in the Rem memory area if retentivity is enabled.Utilization of memory areasThe system

Pagina 26 - Versions

Q1xI2B1B2B3xB4–20No 1No 2No 3I1ParB5B6ParQ2I3I4xREMBytes–12REMBytesBlock no. FunctionMemory areaProgramming IDEC SmartRelay IDEC SmartRelay Manual 107

Pagina 27 - IDEC SmartRelay Manual 13

Programming IDEC SmartRelay 108 IDEC SmartRelay ManualIndication of available memory spaceIDEC SmartRelay shows you the amount of free memory space.P

Pagina 28 - 14 IDEC SmartRelay Manual

IDEC SmartRelay Manual 1094IDEC SmartRelay functionsOrganizationIDEC SmartRelay provides you with various elements in programming mode, which are orga

Pagina 29

IDEC SmartRelay functions110 IDEC SmartRelay Manual4.1 Constants and connectors - CoConstants and connectors (= Co) represent inputs, outputs, memory

Pagina 30 - 16 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 111There are also 16 blank outputs available. These are identified with an x and cannot be reused in a

Pagina 31 - IDEC SmartRelay Manual 17

IDEC SmartRelay functions112 IDEC SmartRelay ManualBacklight flags M25 and M26The M25 flag controls the backlight of the IDEC SmartRelay Display. The

Pagina 32

IDEC SmartRelay functionsIDEC SmartRelay Manual 113Text Display function keysThe Text Display has four function keys that you can use in your circuit

Pagina 33 - IDEC SmartRelay Manual 19

IDEC SmartRelay functions114 IDEC SmartRelay Manual4.2 Basic functions list - GFBasic functions represent simple logical elements of Boolean algebra.

Pagina 34 - 2.1.1 Maximum setup

IDEC SmartRelay functionsIDEC SmartRelay Manual 1154.2.1 ANDCircuit diagram of a series circuit with several normally open contacts:Symbol in IDEC Sma

Pagina 35 - IDEC SmartRelay Manual 21

IDEC SmartRelay Manual xi8.1.4 Special features and expansion options ... 2688.2 Automatic door ...

Pagina 36 - Expansion modules

IDEC SmartRelay functions116 IDEC SmartRelay Manual4.2.2 AND with Edge DetectionSymbol in IDEC SmartRelay:The output of an edge triggered AND is only

Pagina 37

IDEC SmartRelay functionsIDEC SmartRelay Manual 117NAND function logic table4.2.4 NAND with Edge DetectionSymbol in IDEC SmartRelay:The output status

Pagina 38 - 2.1.3 Compatibility

1Cycle3Q2123456789104IDEC SmartRelay functions118 IDEC SmartRelay ManualTiming diagram for the NAND with Edge Detection4.2.5 ORCircuit diagram of a p

Pagina 39

IDEC SmartRelay functionsIDEC SmartRelay Manual 1194.2.6 NOR (not OR)Circuit diagram of a series circuit with several normally closed contacts:Symbol

Pagina 40 - 2.2.1 DIN rail mounting

IDEC SmartRelay functions120 IDEC SmartRelay Manual4.2.7 XOR (exclusive OR)The XOR in a circuit diagram, shown as series circuit with 2 changeover co

Pagina 41 - IDEC SmartRelay Manual 27

IDEC SmartRelay functionsIDEC SmartRelay Manual 1214.3 Special functionsBecause of their different input designation, you can see right away that ther

Pagina 42

IDEC SmartRelay functions122 IDEC SmartRelay ManualConnector X at SF inputsSF inputs connected to connector x are set low. That is, the inputs carry

Pagina 43 - 2.2.2 Wall-mounting

IDEC SmartRelay functionsIDEC SmartRelay Manual 123Accuracy of TBecause of slight tolerances in the characteristics of electronic components, the set

Pagina 44 - 78.5+0.5mm

IDEC SmartRelay functions124 IDEC SmartRelay Manualresumes operation until the time-to-go has expired, for example.To enable this response, however,

Pagina 45

IDEC SmartRelay functionsIDEC SmartRelay Manual 1254.3.6 Calculating the gain and offset of analog valuesA sensor is connected to the analog input and

Pagina 46 - 2.3 Wiring IDEC SmartRelay

xii IDEC SmartRelay ManualA.5 Technical data: FL1B-M08B1S2 ... 307A.6 Technical data: FL1E-H12RCA/FL1E

Pagina 47 - I1 I2 I3 I4L1 N

IDEC SmartRelay functions126 IDEC SmartRelay ManualMathematical ruleActual value Ax =(internal value at input Ax • gain) + offsetGain and offset cal

Pagina 48 - 34 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 127Example of analog valuesA sample application is found in the description of the ”Analog comparator”

Pagina 49

IDEC SmartRelay functions128 IDEC SmartRelay Manual4.4 Special functions list - SFWhen you create your circuit program in IDEC SmartRelay, you find t

Pagina 50 - X-capacitor 2.5 kV, 100 nF

IDEC SmartRelay functionsIDEC SmartRelay Manual 129Stairwell Light Switch(see page 146)REMDual-function switch(see page 148)REMSeven-day time switch(s

Pagina 51

IDEC SmartRelay functions130 IDEC SmartRelay ManualAnalog value monitoring(see Page 182)Analog amplifier(see Page 185)Analog multiplexer(see Page

Pagina 52 - NL1 I1 I2 I3 I4 I5 I6

IDEC SmartRelay functionsIDEC SmartRelay Manual 1314.4.1 On-delayShort descriptionThe output is only set after a configurable on-delay time has expire

Pagina 53 - Current measurement

IDEC SmartRelay functions132 IDEC SmartRelay ManualParameter TNote the defaults for parameter T in Chapter 4.3.2.The time for parameter T can also be

Pagina 54 - 40 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 133The display in programming mode (example):B12 +RTB006 mIf the referenced block (B6, in the exam

Pagina 55 - IDEC SmartRelay Manual 41

IDEC SmartRelay functions134 IDEC SmartRelay ManualThe view in parameter assignment mode (example):T =04:10hT =04:10Ta =02:00hB12B12TB006mTa =02:00ho

Pagina 56 - 42 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 1354.4.2 Off-delayShort descriptionWhen an on-delay is set, the output is reset when the configured ti

Pagina 57 - Analog Input (0-20mA)

IDEC SmartRelay Manual 11Getting started with IDEC SmartRelayHere’s IDEC SmartRelayIDEC SmartRelay is a universal logic module made by IDEC that inte

Pagina 58 - 2.3.4 Connecting outputs

IDEC SmartRelay functions136 IDEC SmartRelay ManualFunctional descriptionOutput Q is set to hi immediately when the input Trg changes to hi.The actua

Pagina 59 - Load: 24 V DC, 0.3 A max

IDEC SmartRelay functionsIDEC SmartRelay Manual 137Parameters TH and TLNote the preset values for the parameters TH and TL in Chapter 4.3.2.The on-del

Pagina 60 - FL1D-K2BM2: Voltage output:

IDEC SmartRelay functions138 IDEC SmartRelay Manual4.4.4 Retentive on-delayShort descriptionA one-shot at the input triggers a configurable on-delay

Pagina 61 - Internal Circuit

IDEC SmartRelay functionsIDEC SmartRelay Manual 139Functional descriptionThe 0 to 1 signal transition at input Trg triggers the current time Ta . Outp

Pagina 62 - Analog Output (0/4 ... 20mA)

TrgT has not expiredTa is expiringQTThe bold section of the timing diagram also appears in the symbol of the wiping relay.IDEC SmartRelay functions140

Pagina 63

IDEC SmartRelay functionsIDEC SmartRelay Manual 141Parameters TH and TLNote the information on parameter T in Chapter 4.3.2.The pulse width TH and the

Pagina 64

IDEC SmartRelay functions142 IDEC SmartRelay ManualSetting the Par parameterView in programming mode (example):B25 1+RTL =02:00sTH =03:00sProtect

Pagina 65 - 2.4 Putting into operation

IDEC SmartRelay functionsIDEC SmartRelay Manual 143Parameters TH and TLNote the information on parameter T in Chapter 4.3.2.The pulse width TH and the

Pagina 66 - 52 IDEC SmartRelay Manual

IDEC SmartRelay functions144 IDEC SmartRelay Manual4.4.8 Random generatorShort descriptionThe output of the random generator is set or reset within a

Pagina 67

EnT isbusyQTLTHThe bold section of the timing diagram also appears in the symbol of the random generator.IDEC SmartRelay functionsIDEC SmartRelay Manu

Pagina 68 - 2.4.2 Operating states

Getting started with IDEC SmartRelay2 IDEC SmartRelay ManualWhich devices are available? IDEC SmartRelay Base is available in two voltage classes:• Cl

Pagina 69 - IDEC SmartRelay Manual 55

IDEC SmartRelay functions146 IDEC SmartRelay Manual4.4.9 Stairwell Light SwitchShort descriptionAn input edge triggers a configurable and retriggerab

Pagina 70 - 56 IDEC SmartRelay Manual

Ta is busyTQTrgT!LT!IDEC SmartRelay functionsIDEC SmartRelay Manual 147Timing diagramFunctional descriptionA 0 to 1 signal transition at input Trg set

Pagina 71

IDEC SmartRelay functions148 IDEC SmartRelay ManualView in parameter assignment mode (example):B9 1T =60:00sTa =06:00sCurrent value of T4.4.10 D

Pagina 72 - 3.1 Connectors

IDEC SmartRelay functionsIDEC SmartRelay Manual 149Parameters T, TL, T! and T!LNote the defaults of the T parameters listed in Chapter 4.3.2.The off-d

Pagina 73 - IDEC SmartRelay Manual 59

IDEC SmartRelay functions150 IDEC SmartRelay ManualIf retentivity is not set, output Q and the expired time are reset after a power failure.Setting t

Pagina 74 - 3.2 Blocks and block numbers

IDEC SmartRelay functionsIDEC SmartRelay Manual 151NoteBecause the FL1E-H12SND does not have a real-time clock, the seven-day time switch function is

Pagina 75

IDEC SmartRelay functions152 IDEC SmartRelay ManualParameter assignment screen formView of the parameter assignment screen form, for example for Cam1

Pagina 76

IDEC SmartRelay functionsIDEC SmartRelay Manual 153Setting the seven-day time switchTo set the on-/off-times:1. Move the cursor to one of the Cam para

Pagina 77 - S1 ... S3

IDEC SmartRelay functions154 IDEC SmartRelay ManualCam1Cam No1 must set the output of the seven-day time switch daily from 06:30 h to 08:00 h.B1

Pagina 78 - 64 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 1554.4.12 Twelve-month time switchShort descriptionThe output is controlled by means of a configurable

Pagina 79 - IDEC SmartRelay Manual 65

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 3Features of the Text DisplayThe Text Display is available with the FL1E series. It provide

Pagina 80

IDEC SmartRelay functions156 IDEC SmartRelay ManualExample 2: Yearly mode on, Monthly mode off, Pulse on, On Time = 2000–03–15, Off Time = 2099–**–**

Pagina 81 - IDEC SmartRelay Manual 67

IDEC SmartRelay functionsIDEC SmartRelay Manual 157Example 4: Yearly mode on, Monthly mode off, Pulse on, On Time = 2008–03–15, Off Time = 2010–**–**:

Pagina 82

IDEC SmartRelay functions158 IDEC SmartRelay ManualExample 6: Yearly mode off, Monthly mode off, Pulse selected, On Time = 2008–03–15, Off Time = ***

Pagina 83 - IDEC SmartRelay’s main menu

IDEC SmartRelay functionsIDEC SmartRelay Manual 159Example 8: Yearly mode on, Monthly mode on, On Time = 2008–**–01, Off Time = 2010–**–05: Starting i

Pagina 84

IDEC SmartRelay functions160 IDEC SmartRelay ManualBackup of the real-time clockThe internal real-time clock of IDEC SmartRelay is buffered against p

Pagina 85 - IDEC SmartRelay Manual 71

IDEC SmartRelay functionsIDEC SmartRelay Manual 1614.4.13 Up/down counterShort descriptionAn input pulse increments or decrements an internal value, d

Pagina 86 - 3.6.3 Circuit program input

IDEC SmartRelay functions162 IDEC SmartRelay ManualParameters On and OffThe on threshold On and the off threshold Off can be provided by the actual v

Pagina 87

IDEC SmartRelay functionsIDEC SmartRelay Manual 163NoteThe system scans the counter limit value cyclically.Thus, if the pulse frequency at the fast in

Pagina 88

IDEC SmartRelay functions164 IDEC SmartRelay Manual4.4.14 Operating hours counterShort descriptionA configured time is triggered with a signal at the

Pagina 89

IDEC SmartRelay functionsIDEC SmartRelay Manual 165Parameter MIThe maintenance interval MI can be provided by the actual value of another already-prog

Pagina 90

Getting started with IDEC SmartRelay4 IDEC SmartRelay ManualIt’s your choiceThe various IDEC SmartRelay Base versions, expansion modules, Text Display

Pagina 91 - IDEC SmartRelay Manual 77

IDEC SmartRelay functions166 IDEC SmartRelay ManualFunctional descriptionThe operating hours counter monitors input En. When En = 1, IDEC SmartRelay

Pagina 92 - 3.6.5 Password

IDEC SmartRelay functionsIDEC SmartRelay Manual 167Setting the Par parameterView in programming mode:B16 1+RMI = 0100h 00 mB16 1+RMI–>

Pagina 93 - No Password

IDEC SmartRelay functions168 IDEC SmartRelay Manual4.4.15 Frequency triggerShort descriptionThe output is set and reset with two configurable frequen

Pagina 94 - 80 IDEC SmartRelay Manual

QOff = 5fa = 9 fa = 10 fa = 8 fa = 5G_TFreOn = 9fa = Input frequencyIDEC SmartRelay functionsIDEC SmartRelay Manual 169Timing diagramFunctional descri

Pagina 95 - IDEC SmartRelay Manual 81

IDEC SmartRelay functions170 IDEC SmartRelay ManualNoteThe “seconds” timebase is here set as permanent default.When you preset a time G_T of 1 s, IDE

Pagina 96 - Stop Prg

IDEC SmartRelay functionsIDEC SmartRelay Manual 1714.4.16 Analog triggerShort descriptionThe output is set and reset at two configurable thresholds.Ga

Pagina 97 - IDEC SmartRelay Manual 83

IDEC SmartRelay functions172 IDEC SmartRelay ManualParameter p (number of decimals)Does not apply to the display of On, Off and Ax values in a messag

Pagina 98 - Mo 09:00

IDEC SmartRelay functionsIDEC SmartRelay Manual 173Setting the Par parameterThe gain and offset parameters are used to adapt the sensors to the releva

Pagina 99 - 2..01234

IDEC SmartRelay functions174 IDEC SmartRelay Manual4.4.17 Analog differential triggerShort descriptionThe output is set and reset depending on a conf

Pagina 100 - 3.6.7 Second circuit program

IDEC SmartRelay functionsIDEC SmartRelay Manual 175Parameter p (number of decimals)Does not apply to the display of On, Off and Ax values in a message

Pagina 101

I7 I8Q1 Q2 Q3 Q44L1 N09I5 I6I2 I3 I4I17255531 2 1 2 1 2 1 26IDEC SmartRelay Base (e.g.: FL1E-H12RCC)Q4Q1 Q2L1 N I2 I

Pagina 102 - ‘OK’, this shows the

IDEC SmartRelay functions176 IDEC SmartRelay ManualSetting the Par parameterThe gain and offset parameters are used to adapt the sensors to the relev

Pagina 103 - T =00:00s

IDEC SmartRelay functionsIDEC SmartRelay Manual 1774.4.18 Analog comparatorShort descriptionThe output is set and reset depending on the difference Ax

Pagina 104

IDEC SmartRelay functions178 IDEC SmartRelay ManualParameter p (number of decimals)Does not apply to Ax, Ay, On, Off and  values displayed in a mess

Pagina 105 - Mo 09:30

IDEC SmartRelay functionsIDEC SmartRelay Manual 179Setting the Par parameterThe gain and offset parameters are used to adapt the sensors to the releva

Pagina 106 - 3.6.8 Deleting a block

IDEC SmartRelay functions180 IDEC SmartRelay ManualConfiguration (example):B3 1+On =+00015Off =+00005Protection modeOn thresholdOff thresholdPre

Pagina 107 - 3.6.9 Deleting block groups

IDEC SmartRelay functionsIDEC SmartRelay Manual 181Reducing the input response of the analog comparatorYou can selectively delay the output of an anal

Pagina 108 - AQ in Stop

IDEC SmartRelay functions182 IDEC SmartRelay Manual4.4.19 Analog watchdogShort descriptionThis special function saves the process variable of an anal

Pagina 109 - AQ2:4..20mA

IDEC SmartRelay functionsIDEC SmartRelay Manual 183• Analog comparator (actual value Ax - Ay, see Chapter 4.4.18)• Analog trigger (actual value Ax, se

Pagina 110 - Password?

IDEC SmartRelay functions184 IDEC SmartRelay ManualSetting the Par parameterThe gain and offset parameters are used to adapt the used sensors to the

Pagina 111 - S/W Time:

IDEC SmartRelay functionsIDEC SmartRelay Manual 1854.4.20 Analog amplifierShort descriptionThis special function amplifies the value of an analog inpu

Pagina 112 - 98 IDEC SmartRelay Manual

Revision History Date Manual No. Description November, 2008 B-1090(0) First print December, 2008 B-1090(1) Sensor connections for IDEC SmartRelay:

Pagina 113

I7 I8Q1 Q2 Q3 Q44L+ M46509I5 I6I2 I3 I4I17255531 2 1 2 1 2 1 2IDEC SmartRelay Base (e.g.: FL1E-H12RCE)Q3 Q4Q1

Pagina 114

IDEC SmartRelay functions186 IDEC SmartRelay ManualAnalog outputAnalog output can only process values between 0 and 1000.Connect an Analog amplifier

Pagina 115 - 3.6.15 Synchronization

IDEC SmartRelay functionsIDEC SmartRelay Manual 187• When the type of analog outputs is set to 4-20mA:When internal values less than zero are inputted

Pagina 116 - 102 IDEC SmartRelay Manual

IDEC SmartRelay functions188 IDEC SmartRelay ManualIn the block diagram below, the analog output module operates as the lower part of the timing char

Pagina 117 - IDEC SmartRelay Manual 103

IDEC SmartRelay functionsIDEC SmartRelay Manual 189Scaling an analog input valueYou can influence the analog input value of a potentiometer by interco

Pagina 118 - Programming IDEC SmartRelay

IDEC SmartRelay functions190 IDEC SmartRelay Manual4.4.21 Latching relayShort descriptionInput S sets output Q, input R resets output Q again.SRQTimi

Pagina 119 - IDEC SmartRelay Manual 105

IDEC SmartRelay functionsIDEC SmartRelay Manual 1914.4.22 Current impulse relay Short descriptionA short pulse at the input sets and resets the output

Pagina 120 - 106 IDEC SmartRelay Manual

IDEC SmartRelay functions192 IDEC SmartRelay ManualStatus diagram*: RS or SR**: Triggering signal is effective, because S and R = 0.Depending on your

Pagina 121 - Example:

IDEC SmartRelay functionsIDEC SmartRelay Manual 193NoteIf Trg = 0 and Par = RS, the special function “Current impulse relay ” corresponds with the sp

Pagina 122 - Rem = 247

IDEC SmartRelay functions194 IDEC SmartRelay Manual• Current Character Set: which character set is selected for the display of message textsNoteMessa

Pagina 123 - IDEC SmartRelay functions

IDEC SmartRelay functionsIDEC SmartRelay Manual 195Chinese Character SetThe IDEC SmartRelay base module and Text Display support the Chinese character

Pagina 124 - 110 IDEC SmartRelay Manual

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 7FL1B-J2B2I1PEINPUT2x(0..10V/0..20mA)L+ M09M1 U1 M2 U2I24L+ MRUN/STOP36 5353FL1D-K2B2Power

Pagina 125 - RUN/STOP

IDEC SmartRelay functions196 IDEC SmartRelay ManualMessage Text Function BlockSymbol in IDEC SmartRelayWiring DescriptionInput En A 0 to 1 transition

Pagina 126 - 112 IDEC SmartRelay Manual

IDEC SmartRelay functionsIDEC SmartRelay Manual 197RestrictionA maximum of 50 message texts are available.Functional descriptionWhen IDEC SmartRelay i

Pagina 127 - IDEC SmartRelay Manual 113

IDEC SmartRelay functions198 IDEC SmartRelay ManualExampleThis is how two message texts could be shown:Display field of IDEC SmartRelay in RUN mode20

Pagina 128 - 4.2 Basic functions list - GF

IDEC SmartRelay functionsIDEC SmartRelay Manual 199Example: Tick Message Character by CharacterThe following illustration shows a one-line, 24-charact

Pagina 129 - Normally Closed

IDEC SmartRelay functions200 IDEC SmartRelay ManualInput P configurationFrom the input P, you configure the following characteristics of the message

Pagina 130 - 4.2.3 NAND (not AND)

TickType Ch by ChB33 3+/Tick Type: Character by Character (Ch by Ch) or Line by Line (Ln by Ln)IDEC SmartRelay functionsIDEC SmartRelay Manual 2015

Pagina 131

IDEC SmartRelay functions202 IDEC SmartRelay ManualSpecial functionParameter or process variable visible in a message textTimersOn-delay T, TaOff-del

Pagina 132 - 12345678910

IDEC SmartRelay functionsIDEC SmartRelay Manual 203For timers, a message text can also display the remaining time. “Remaining time” refers to how much

Pagina 133 - 4.2.6 NOR (not OR)

IDEC SmartRelay functions204 IDEC SmartRelay ManualKey input simulation in the active message textYou can enable the four cursor keys C , C , C

Pagina 134 - 4.2.7 XOR (exclusive OR)

IDEC SmartRelay functionsIDEC SmartRelay Manual 2054.4.24 SoftkeyShort descriptionThis special function has the effect of a mechanical pushbutton or s

Pagina 135 - 4.3 Special functions

Getting started with IDEC SmartRelay8 IDEC SmartRelay ManualFL1D-K2BM2V1+OUTPUT 2x(0..10V or 0/ 4..20mA)L+M36RU N / ST OP179988M1PEM2V2+4L+M2111012539

Pagina 136 - 4.3.2 Time response

IDEC SmartRelay functions206 IDEC SmartRelay ManualFunctional descriptionIn parameter assignment mode, the output is set with a signal at input En, i

Pagina 137 - 4.3.4 Retentivity

IDEC SmartRelay functionsIDEC SmartRelay Manual 2075. To change to the start state:Press or 6. To change the start state:Press or B33 +/On/Of

Pagina 138 - 4.3.5 Parameter protection

IDEC SmartRelay functions208 IDEC SmartRelay Manual4.4.25 Shift registerShort descriptionYou can use the shift register function to read the value of

Pagina 139 - -10000 +10000

TrgInQDir S1 0 1 0 1 1 0 1 S2 0 0 1 0 1 1 1 S3 0 0 0 1 0 1 0 S4 0000101 S5 1 0 0 0 0 1 0 S6 1 1 0 0 0 0

Pagina 140 - 126 IDEC SmartRelay Manual

IDEC SmartRelay functions210 IDEC SmartRelay Manual4.4.26 Analog MultiplexerShort descriptionThis special function outputs one of four predefined ana

Pagina 141 - IDEC SmartRelay Manual 127

IDEC SmartRelay functionsIDEC SmartRelay Manual 211Parameter p (number of decimals)Applies only to the values displayed in a message text.EnSS1S2AQV1V

Pagina 142 - 128 IDEC SmartRelay Manual

IDEC SmartRelay functions212 IDEC SmartRelay Manual4.4.27 Analog Ramp ControlShort descriptionThe Analog ramp control instruction allows the output t

Pagina 143

IDEC SmartRelay functionsIDEC SmartRelay Manual 213Parameter Level 1 and Level 2: Levels to be reachedRange of values for each level: -10,000 to +2

Pagina 144

IDEC SmartRelay functions214 IDEC SmartRelay ManualParameters L1, L2The analog values for the parameters L1 and L2 can be derived from another alread

Pagina 145 - 4.4.1 On-delay

IDEC SmartRelay functionsIDEC SmartRelay Manual 215Functional descriptionIf the input En is set, then the function sets the current level to StSp + Of

Pagina 146 - T =04:10h

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 9Text Display Communication interface Power supplyThe Text Display includes a wider displ

Pagina 147

IDEC SmartRelay functions216 IDEC SmartRelay ManualView in parameter assignment mode:B3 1L1 =+04000L2B020AQ =00250B3 2StSp=00222Rate=0050

Pagina 148

IDEC SmartRelay functionsIDEC SmartRelay Manual 217Parameter SP: Set-value assignmentRange of values: -10,000 to +20,000KC: GainRange of values: 0

Pagina 149 - 4.4.2 Off-delay

IDEC SmartRelay functions218 IDEC SmartRelay ManualParameters SP and MqThe set-value SP and the value for Mq can be provided by another already-progr

Pagina 150 - 4.4.3 On-/Off-delay

IDEC SmartRelay functionsIDEC SmartRelay Manual 219Timing diagramThe nature, manner and speed with which the AQ changes depend on the parameters KC an

Pagina 151

IDEC SmartRelay functions220 IDEC SmartRelay ManualNoteFor further information on the controller basics please refer to the online help for WindLGC.T

Pagina 152 - 4.4.4 Retentive on-delay

IDEC SmartRelay functionsIDEC SmartRelay Manual 221Setting the Par parameterView in programming mode (example):B3 1+/SPB020B3 2+/KC =10.00TI =

Pagina 153 - IDEC SmartRelay Manual 139

IDEC SmartRelay functions222 IDEC SmartRelay Manual4.4.29 Pulse Width Modulator (PWM)Short descriptionThe Pulse Width Modulator (PWM) instruction mod

Pagina 154 - is expiring

IDEC SmartRelay functionsIDEC SmartRelay Manual 223Parameters p (number of decimals)Parameter p applies only to the display of the Ax value in a messa

Pagina 155 - is running

IDEC SmartRelay functions224 IDEC SmartRelay Manual2. An analog value of 300 (range 0...1000) as the value for Ax must be modulated to a digital sign

Pagina 156 - B25 2

IDEC SmartRelay functionsIDEC SmartRelay Manual 225View in parameter assignment mode:B1 2B =+00000T =00:04sB1 1Min=+00000Max=+01000A = 1.00Pr

Pagina 157 - IDEC SmartRelay Manual 143

Getting started with IDEC SmartRelay10 IDEC SmartRelay ManualExpansion moduleDigital module FL1B-M Number of Inputs and Outputs B1: 24V DC B2:

Pagina 158 - 4.4.8 Random generator

IDEC SmartRelay functions226 IDEC SmartRelay ManualParameters V1...V4The analog values for the parameters V1...V4 can be derived from another already

Pagina 159

IDEC SmartRelay functionsIDEC SmartRelay Manual 227Functional DescriptionThe analog math function combines the four operands and three operators to fo

Pagina 160 - 4.4.9 Stairwell Light Switch

IDEC SmartRelay functions228 IDEC SmartRelay ManualExamplesThe following tables show some simple example analog math block parameters, and the result

Pagina 161 - T!L =00:10s

IDEC SmartRelay functionsIDEC SmartRelay Manual 229Setting the Par parameterThe following illustration shows the view in programming mode that corresp

Pagina 162 - 4.4.10 Dual-function switch

IDEC SmartRelay functions230 IDEC SmartRelay Manual4.4.31 Analog math error detectionShort descriptionThe analog math error detection block sets an o

Pagina 163 - IDEC SmartRelay Manual 149

IDEC SmartRelay functionsIDEC SmartRelay Manual 231Analog math error detection logic tableIn the table below, Err represents the parameter of the anal

Pagina 164 - 4.4.11 Seven-day time switch

IDEC SmartRelay functions232 IDEC SmartRelay ManualSetting the Par parameterThe parameters MathBN, AutoRst, and Err can be set in programming mode or

Pagina 165 - IDEC SmartRelay Manual 151

IDEC SmartRelay Manual 2335Configuring IDEC SmartRelayParameter assignment refers to the configuration of the block parameters. You can set delay time

Pagina 166

Configuring IDEC SmartRelay234 IDEC SmartRelay Manual5.1 Selecting parameter assignment modePress ESC to change from RUN to parameter assignment mode

Pagina 167 - Chapter 4.3.2

Configuring IDEC SmartRelayIDEC SmartRelay Manual 235IDEC SmartRelay shows the main menu of the programming mode:>Program.. Card.. Setup.. Start• S

Pagina 168 - Off=08:00

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 11SymbolsVersion with display unit is equipped with 8 inputs and 4 outputsVersion without d

Pagina 169 - IDEC SmartRelay Manual 155

Configuring IDEC SmartRelay236 IDEC SmartRelay Manual5.1.2 Selecting the parametersTo select a parameter:1. On the parameter assignment menu, select

Pagina 170 - 156 IDEC SmartRelay Manual

Configuring IDEC SmartRelayIDEC SmartRelay Manual 2375.1.3 Modifying parametersYou first select the parameter you want to edit (see Chapter 5.1.2).You

Pagina 171 - IDEC SmartRelay Manual 157

Configuring IDEC SmartRelay238 IDEC SmartRelay ManualCurrent value of a counterView of a counter parameter in parameter assignment mode:B3On =001234O

Pagina 172 - 158 IDEC SmartRelay Manual

Configuring IDEC SmartRelayIDEC SmartRelay Manual 2395.2 Setting the default values for IDEC Smart-RelayYou can set the following default values for a

Pagina 173 - IDEC SmartRelay Manual 159

Configuring IDEC SmartRelay240 IDEC SmartRelay ManualStart screen settingsYou can select the default setting for the start screen that displays on ID

Pagina 174 - 160 IDEC SmartRelay Manual

Configuring IDEC SmartRelayIDEC SmartRelay Manual 241IDEC SmartRelay shows the following display.Set ClockMo 15:30YYYY-MM-DD2008-05-26The cursor is po

Pagina 175 - 4.4.13 Up/down counter

Configuring IDEC SmartRelay242 IDEC SmartRelay ManualIDEC SmartRelay shows the following display:Contrast–... ...+8. To change the display contrast

Pagina 176 - Internal count

Configuring IDEC SmartRelayIDEC SmartRelay Manual 2435.2.3 Setting the menu languageThe language of the IDEC SmartRelay menus can be one of ten predef

Pagina 177

Configuring IDEC SmartRelay244 IDEC SmartRelay Manual5.2.4 Setting the number of AIs in the base moduleFL1E-H12RCE/FL1E-B12RCE and FL1E-H12SND suppor

Pagina 178 - Short description

Configuring IDEC SmartRelayIDEC SmartRelay Manual 2455.2.5 Setting the start screenYou can select the default setting for the start screen that IDEC S

Pagina 179

Getting started with IDEC SmartRelay12 IDEC SmartRelay ManualVersionsThe following IDEC SmartRelay versions are available:(1): Of those can be used al

Pagina 180 - MN = 30 - (100 % 30)

Configuring IDEC SmartRelay246 IDEC SmartRelay Manual

Pagina 181 - B16 3+R

IDEC SmartRelay Manual 2476IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay provides the following cartridges for program storage a

Pagina 182 - 4.4.15 Frequency trigger

IDEC SmartRelay memory and battery cartridge (card)248 IDEC SmartRelay Manual• Send circuit programs by mail• Write and test your circuit program at

Pagina 183 - G_T=01:00s

IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay Manual 249Compatibility (Old memory cartridges in newer IDEC SmartRelay modules) ..

Pagina 184 - Off =0005

IDEC SmartRelay memory and battery cartridge (card)250 IDEC SmartRelay Manual6.1 Security function (CopyProtect)The secuirty function provides copy p

Pagina 185 - 4.4.16 Analog trigger

IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay Manual 251Assigning a security functionTo assign a circuit program and copy protect

Pagina 186 - 172 IDEC SmartRelay Manual

IDEC SmartRelay memory and battery cartridge (card)252 IDEC SmartRelay Manual6.2 Inserting and removing memory and battery cartridgesWhen you remove

Pagina 187 - B =+00000

IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay Manual 253Removing the memory cartridge, battery cartridge or combined memory/batte

Pagina 188 - 174 IDEC SmartRelay Manual

IDEC SmartRelay memory and battery cartridge (card)254 IDEC SmartRelay Manual6.3 Copying data from IDEC SmartRelay to the memory cartridgeTo copy the

Pagina 189 - Off = On +

IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay Manual 255When IDEC SmartRelay has finished copying, it automatically returns you t

Pagina 190 - Decimals in the message text

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 13Expansion modulesThe following expansion modules can be connected to IDEC SmartRelay: (1)

Pagina 191 - 4.4.18 Analog comparator

IDEC SmartRelay memory and battery cartridge (card)256 IDEC SmartRelay Manual6.4 Copying data from the memory cartridge to IDEC SmartRelayYou can cop

Pagina 192 - 178 IDEC SmartRelay Manual

IDEC SmartRelay memory and battery cartridge (card)IDEC SmartRelay Manual 257When IDEC SmartRelay has finished copying, it opens the main menu:>Pro

Pagina 193 - Off =+00000

IDEC SmartRelay memory and battery cartridge (card)258 IDEC SmartRelay Manual5. Move the ’>’ cursor to ’Card  IDEC SmartRelay’:Press or = IDEC

Pagina 194

IDEC SmartRelay Manual 2597IDEC SmartRelay softwareWindLGC is available as a programming package for the PC. This software provides many features, for

Pagina 195

IDEC SmartRelay software260 IDEC SmartRelay ManualWindLGCWindLGC runs under Windows 7®, Windows Vista®, Windows 98®, Windows NT 4.0®, Windows Me®, Wi

Pagina 196 - 4.4.19 Analog watchdog

IDEC SmartRelay softwareIDEC SmartRelay Manual 2617.1 Connecting IDEC SmartRelay to a PCConnecting the PC cableTo connect IDEC SmartRelay to a PC, you

Pagina 197 - to Aen + 

IDEC SmartRelay software262 IDEC SmartRelay ManualClosing the PCIDEC SmartRelay modeWhen the data transfer is completed, the connection to the PC is

Pagina 198 - 2 = 00000

IDEC SmartRelay Manual 2638ApplicationsWe have provided a small collection of applications in this manual to give you an impression of the versatility

Pagina 199 - 4.4.20 Analog amplifier

Applications264 IDEC SmartRelay ManualNoteIDEC SmartRelay applications are available to all our customers free of charge. The examples provided are n

Pagina 200 - 186 IDEC SmartRelay Manual

ApplicationsIDEC SmartRelay Manual 2658.1 Stairway or corridor lighting8.1.1 Requirements for a stairway lighting systemThe basic requirements for a s

Pagina 201 - IDEC SmartRelay Manual 187

Getting started with IDEC SmartRelay14 IDEC SmartRelay ManualCertification and approvalsIDEC SmartRelay is certified to cULus and FM. • cULus Haz. Loc

Pagina 202 - 188 IDEC SmartRelay Manual

Applications266 IDEC SmartRelay ManualLighting system with current impulse relay Function of a lighting system with current impulse relay :• Press an

Pagina 203 - B =–00300

ApplicationsIDEC SmartRelay Manual 267Wiring of a lighting system with FL1E-H12RCCThe external wiring of a lighting system with an IDEC SmartRelay is

Pagina 204 - 4.4.21 Latching relay

Applications268 IDEC SmartRelay ManualDual-function switch with IDEC SmartRelayOutput Q1 is set for the duration of a preset time TH with a pulse sig

Pagina 205 - 4.4.22 Current impulse relay

ApplicationsIDEC SmartRelay Manual 2698.2 Automatic doorYou often find automatic door control systems at the entrance to supermarkets, public building

Pagina 206 - B29 R

Applications270 IDEC SmartRelay Manual8.2.2 Conventional solutionK1 K2K2 K1K3 K3S2 S1K3B1 B2 K3K4K4B2K3B1S2L1NAuxiliary circuitOpen Close Open doorWa

Pagina 207 - 4.4.23 Message texts

ApplicationsIDEC SmartRelay Manual 271Wiring of a door control system with FL1E-H12RCCComponents used• K1 contactor relay (open)• K2 contactor relay (

Pagina 208

Applications272 IDEC SmartRelay ManualDoor control system with IDEC SmartRelaycircuit diagramThis is what the circuit diagram of the conventional sol

Pagina 209 - IDEC SmartRelay Manual 195

ApplicationsIDEC SmartRelay Manual 2738.2.4 Special features and expansion optionsOptions for increasing comfort and user friendliness are, for exampl

Pagina 210 - Message Text Function Block

Applications274 IDEC SmartRelay ManualBlock diagram of the extended IDEC SmartRelay solutionxxxxI1I2T= 10 sxI5Q2I4Q1Q2xQ1I1I2I3I6Detecting motionCam1

Pagina 211 - IDEC SmartRelay Manual 197

ApplicationsIDEC SmartRelay Manual 275Detecting motionDuring business hours, the motion detector B1 initiates the opening of the door when somebody wa

Pagina 212

Getting started with IDEC SmartRelayIDEC SmartRelay Manual 15Marine certification requires the surge protective device what manufactured by DEHN+SÖHNE

Pagina 213 - IDEC SmartRelay Manual 199

Applications276 IDEC SmartRelay Manual8.3 Air-conditioning system8.3.1 Requirements for an air-conditioning systemThe air-conditioning system supplie

Pagina 214 - Priority

ApplicationsIDEC SmartRelay Manual 277The circuit diagram for conventional solutions is as follows:K1 K5K5S1S0K3K2L1NS2K1v>S2H1K4S3v>K5H2K2 K4Au

Pagina 215 - B33 5+/

Applications278 IDEC SmartRelay ManualComponents used• K1 contactor relay• K2 contactor relay•S0 (normally closed contact) STOP pushbutton•S1 (normal

Pagina 216 - , A, B, Ax, Aen

ApplicationsIDEC SmartRelay Manual 2798.3.2 Advantages of using IDEC SmartRelayThe IDEC SmartRelay solution requires less switchgear. That saves you i

Pagina 217 - IDEC SmartRelay Manual 203

Applications280 IDEC SmartRelay ManualYou can also generate a message at output Q4:Q3Q4Error MessegeThe relay contacts of output Q4 are always closed

Pagina 218 - 204 IDEC SmartRelay Manual

ApplicationsIDEC SmartRelay Manual 2818.4 Factory doorThe entrance to a company’s premises is often closed with a gate. The gate is only opened to let

Pagina 219 - 4.4.24 Softkey

Applications282 IDEC SmartRelay Manual8.4.2 Previous solution Various control systems are used to operate automatic gates. The circuit diagram below

Pagina 220 - Start=On

ApplicationsIDEC SmartRelay Manual 283Components used• K1 contactor relay• K2 contactor relay•S0 (normally closed contact) STOP pushbutton•S1 (normall

Pagina 221 - Start=Off

Applications284 IDEC SmartRelay Manual8.4.3 Extended IDEC SmartRelay solutionOur extended control circuit is to open the gate automatically when the

Pagina 222 - 4.4.25 Shift register

ApplicationsIDEC SmartRelay Manual 2858.5 Centralized control and monitoring of several factory doorsOften, a company’s premises can be entered at se

Pagina 223 - B3 R

IDEC SmartRelay Manual iSafety guidelinesThis manual contains notices you have to observe in order to ensure your personal safety, as well as to preve

Pagina 224 - 4.4.26 Analog Multiplexer

Getting started with IDEC SmartRelay16 IDEC SmartRelay Manual

Pagina 225 - IDEC SmartRelay Manual 211

Applications286 IDEC SmartRelay Manual8.5.1 Requirements for a gate control system• Every gate is opened and closed by means of a cord-operated switc

Pagina 226 - 4.4.27 Analog Ramp Control

ApplicationsIDEC SmartRelay Manual 287Components used• K1 contactor relay open• K2 contactor relay close•S0 (normally open contact) cord operated swit

Pagina 227

Applications288 IDEC SmartRelay ManualBlock diagram of the IDEC SmartRelay solutionThe OPEN GATE and CLOSE GATE pushbuttons initiate the gate motion,

Pagina 228 - 214 IDEC SmartRelay Manual

ApplicationsIDEC SmartRelay Manual 2898.6 Luminous rowsWhen planning lighting systems for commercial locations, the type and number of lamps used is d

Pagina 229

Applications290 IDEC SmartRelay Manual8.6.2 Previous solutionB1L1NE1E1lx>K6E5K5E4K4E3K3E2K3K4K5 K6S1 S2S3 S4K1 K2K2K2K1The lamps are switched on a

Pagina 230 - 4.4.28 PI controller

ApplicationsIDEC SmartRelay Manual 2918.6.3 Luminous row control system with FL1E-H12RCCL1 N I6 I7 I8Q1 Q2 Q3 Q4L1NE2 E3 E4B1lx<E5S1 S2 S3 S4I4 I5I

Pagina 231

Applications292 IDEC SmartRelay ManualBlock diagram of the IDEC SmartRelay solutionAdvantages of the IDEC SmartRelay solution• You can connect the la

Pagina 232 - 218 IDEC SmartRelay Manual

ApplicationsIDEC SmartRelay Manual 2938.7 Service water pumpThe use of rainwater as an addition to the drinking water supply is gaining importance. Th

Pagina 233 - IDEC SmartRelay Manual 219

Applications294 IDEC SmartRelay Manual8.7.1 Requirements for a control system of a service water pump• Service water must be available at all times.

Pagina 234 - 220 IDEC SmartRelay Manual

ApplicationsIDEC SmartRelay Manual 2958.7.3 Service water pump system with FL1E-H12RCCL1 N I4 I5 I6 I7 I8Q1 Q2 Q3 Q4K1 Y1S4S3L1NS1S2p<I1 I2 I31

Pagina 235

IDEC SmartRelay Manual 172IDEC SmartRelay installation and wiringGeneral guidelinesPlease note the following guidelines for installing and wiring you

Pagina 236 - 222 IDEC SmartRelay Manual

Applications296 IDEC SmartRelay ManualBlock diagram of the IDEC SmartRelay solution8.7.4 Special features and expansionsThe block diagram shows how y

Pagina 237 - IDEC SmartRelay Manual 223

IDEC SmartRelay Manual 297ATechnical dataA.1 General technical dataCriterionTested in accordance withValuesIDEC SmartRelay BaseDimensions (WxHxD)Weigh

Pagina 238 - 224 IDEC SmartRelay Manual

Technical data298 IDEC SmartRelay ManualNote: Use a surge absorber, noise cut transformer, or noise filter to protect products rated at 12/24V DC or

Pagina 239 - : 0: Reset value of AQ to 0

Technical dataIDEC SmartRelay Manual 299A.2 Technical data: FL1E-H12RCC/FL1E-B12RCCFL1E-H12RCCFL1E-B12RCCPower supplyInput voltage 100...240 V AC/DC

Pagina 240

Technical data300 IDEC SmartRelay ManualInput current at• Signal 0• Signal 1• Signal 0• Signal 1< 0.03 mA AC> 0.08 mA AC< 0.03 mA DC> 0.

Pagina 241 - IDEC SmartRelay Manual 227

Technical dataIDEC SmartRelay Manual 301Notice: For fluorescent lamps with capacitors, the technical data of fluorescent lamp ballasts must also be co

Pagina 242 - 228 IDEC SmartRelay Manual

Technical data302 IDEC SmartRelay ManualA.3 Technical data: FL1B-M08C2R2FL1B-M08C2R2Power supplyInput voltage 100...240 V AC/DCPermissible range 85 .

Pagina 243 - IDEC SmartRelay Manual 229

Technical dataIDEC SmartRelay Manual 303Delay time at • 0 to 1 : 120 V AC: 240 V AC: 120 V DC: 240 V DC• 1 to 0 : 120 V AC: 240 V AC: 120 V DC: 240 V

Pagina 244 - 230 IDEC SmartRelay Manual

Technical data304 IDEC SmartRelay ManualNotice: For fluorescent lamps with capacitors, the technical data of fluorescent lamp ballasts must also be c

Pagina 245

Technical dataIDEC SmartRelay Manual 305A.4 Technical data: FL1E-H12SNDFL1E-H12SNDPower supplyInput voltage 24 V DCPermissible range 20.4 ... 28.8 V D

Pagina 246 - Err=ZD/OF

IDEC SmartRelay installation and wiring18 IDEC SmartRelay ManualWhat you must note when installingIDEC SmartRelay is designed for fixed and enclosed

Pagina 247 - Configuring IDEC SmartRelay

Technical data306 IDEC SmartRelay Manual(1): When FL1E-H12SND or FL1B-M08B1S2 are switched on, signal 1 is sent to the digital outputs for about 50 m

Pagina 248 - ...Press

Technical dataIDEC SmartRelay Manual 307A.5 Technical data: FL1B-M08B1S2 FL1B-M08B1S2Power supplyInput voltage 24 V DCPermissible range 20.4 ... 28.8

Pagina 249 - Setup

Technical data308 IDEC SmartRelay Manual(1): 8 V DC (Version 1 to 4 specifications)(2): 1.0 mA (Version 1 to 4 specifications)(3): 1.5 mA (Version 1

Pagina 250 - Ta =06:00s

Technical dataIDEC SmartRelay Manual 309A.6 Technical data: FL1E-H12RCA/FL1E-B12RCAFL1E-H12RCAFL1E-B12RCAPower supplyInput voltage 24 V AC/DCPermiss

Pagina 251 - 5.1.3 Modifying parameters

Technical data310 IDEC SmartRelay ManualDigital inputsNumber 8,optional P action or N actionElectrical isolation NoHigh speed inputs not applicable

Pagina 252

Technical dataIDEC SmartRelay Manual 311Notice: For fluorescent lamps with capacitors, the technical data of fluorescent lamp ballasts must also be co

Pagina 253 - IDEC SmartRelay Manual 239

Technical data312 IDEC SmartRelay ManualA.7 Technical data: FL1B-M08D2R2FL1B-M08D2R2Power supplyInput voltage 24 V AC/DCPermissible range 20.4 ... 26

Pagina 254 - Prg Name

Technical dataIDEC SmartRelay Manual 313Notice: For fluorescent lamps with capacitors, the technical data of fluorescent lamp ballasts must also be co

Pagina 255 - YYYY-MM-DD

Technical data314 IDEC SmartRelay ManualA.8 Technical data: FL1E-H12RCE/FL1E-B12RCE and FL1B-M08B2R2FL1E-H12RCEFL1E-B12RCEFL1B-M08B2R2Power supplyI

Pagina 256 - Contrast

Technical dataIDEC SmartRelay Manual 315Delay time at • 0 to 1• 1 to 0typ. 1.5 ms<1.0 ms (I3 ... I6)typ. 1.5 ms<1.0 ms (I3 ... I6)typ. 1.5 ms

Pagina 257 - IDEC SmartRelay Manual 243

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 19These measures are referred to as basic measures.Carrying out testsYou must, however,

Pagina 258 - 244 IDEC SmartRelay Manual

Technical data316 IDEC SmartRelay ManualNotice: For fluorescent lamps with capacitors, the technical data of fluorescent lamp ballasts must also be c

Pagina 259 - StartScreen

0.10.20.30.40.5246810Switching cycles/millionSwitched current/AMaximum 10 AMaximum 10 AMaximum 10 AMaximum 0.2 AMaximum 0.1 A12/24 V AC/DC100/110 V AC

Pagina 260

Technical data318 IDEC SmartRelay ManualA.10 Technical data: FL1B-J2B2FL1B-J2B2Power supplyInput voltage 12/24 V DCPermissible range 10.8 ... 28.8 V

Pagina 261 - IDEC SmartRelay memory

Technical dataIDEC SmartRelay Manual 319A.11 Technical data: FL1D-K2B2, FL1D-K2BM2(1) Voltage output: If short-circuit protection or overcurrent prot

Pagina 262 - 248 IDEC SmartRelay Manual

Technical data320 IDEC SmartRelay ManualA.12 Technical data: Text Display(1) Backlight lifetime is defined as: The final brightness is 50% of the ori

Pagina 263 - IDEC SmartRelay Manual 249

IDEC SmartRelay Manual 321BDetermining the cycle timeThe program cycle is the complete execution of the circuit program, that is, primarily the readin

Pagina 264

Determining the cycle time322 IDEC SmartRelay ManualTest program1. Create the test program by linking an output to a frequency trigger and connecting

Pagina 265 - CopyProtect:

Determining the cycle timeIDEC SmartRelay Manual 323ExplanationThe inverted marker block changes its output signal at each program execution. Thus, on

Pagina 266

Determining the cycle time324 IDEC SmartRelay Manual

Pagina 267 - IDEC SmartRelay Manual 253

IDEC SmartRelay Manual 325CIDEC SmartRelay without display Because some specific applications do not require operator control and monitoring units suc

Pagina 268

IDEC SmartRelay installation and wiring20 IDEC SmartRelay Manual2.1 Modular IDEC SmartRelay setup2.1.1 Maximum setupAs defined in Chapter 1, IDEC Sma

Pagina 269

IDEC SmartRelay without display 326 IDEC SmartRelay ManualOperating characteristicsIDEC SmartRelay is ready for operation when power is switched on.

Pagina 270 - 256 IDEC SmartRelay Manual

IDEC SmartRelay without display IDEC SmartRelay Manual 327Reading current dataWindLGC (see Chapter 7) provides an online test for reading the current

Pagina 271

IDEC SmartRelay without display 328 IDEC SmartRelay Manual

Pagina 272 - CopyProtect

>StopSet ParamSetPrg Name>Stop/>Yes>Memory?Show available memory space (Chapter 3.8)>AQ>Edit Name>Edit PrgEditing the program (Ch

Pagina 273 - IDEC SmartRelay software

>Card–>> –>Card>CopyProtect>Clock..>LCD>BM AI NUM>Menu Lang>Set Clock>Sync>S/W Time>Contrast>BackLightTrans

Pagina 274

Press ESCNo Program>StopSet ParamMsg Config Set ..>ClockLCDMenu Lang>SetupMsg ConfigStartMenu overviewSee “Main menu” Mo 09:002008-05-26See “

Pagina 275

IDEC SmartRelay menu structure332 IDEC SmartRelay ManualStart Menu (base module in RUN)>StopSet ParamSet Msg ConfigEverythingclear?SmartRelay Mo 0

Pagina 276

IDEC SmartRelay Manual 333EType NumbersTable A IDEC SmartRelay ModulesName Type Number Rated Power VoltageInput Type (Digital)Input Type (Analog)Outpu

Pagina 277 - Applications

Type Numbers334 IDEC SmartRelay ManualCable and Accessories Table BName Function Type NumberWindLGC Exclusive Programming Software for IDEC SmartRela

Pagina 278

IndexIDEC SmartRelay Manual 335IndexAAIs in Base Module 244AM See Analog moduleAmplifieranalog 185Analogcomparator 177values 125Analog amplifier 185An

Pagina 279 - 8.1.2 Previous solution

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 21With any setup, you can plug in an analog output module, which has the maximum of two

Pagina 280 - 266 IDEC SmartRelay Manual

Index336 IDEC SmartRelay Manualassigning 77Circuit program size 103Circuit programsarchiving 247reproduce 247send by mail 248Closing the programming m

Pagina 281 - IDEC SmartRelay Manual 267

IndexIDEC SmartRelay Manual 337Factory door 281factory doorcontrolling 285monitoring 285lightingcorridor 265stairway 265Luminous rows 289Service water

Pagina 282 - 268 IDEC SmartRelay Manual

Index338 IDEC SmartRelay ManualLatching relay 190LCD lifetimeText Display 320LED 326Levels 113ListBF 109BN 109Co 109, 110GF 114SF 109, 128Ln by Ln tic

Pagina 283 - 8.2 Automatic door

IndexIDEC SmartRelay Manual 339Programming mode 69OR 118Order numbers 333Outputs 110Analog outputs 111blank 58, 111connecting 44Digital outputs 110Ove

Pagina 284 - Open Close Open door

Index340 IDEC SmartRelay ManualResources 105Retentive memory 103Retentive on-delay 138Retentivity 123enabling/disablingRetentivity setting 90Rulesfour

Pagina 285 - Open Close

IndexIDEC SmartRelay Manual 341Comfort 148Stairwell light 146Twelve-month time switch 155Stairwell light switch 146Start 84Start screen 245Startup cha

Pagina 286 - CloseClose

Index342 IDEC SmartRelay ManualVVerification 91Voltage levels 113Voltage supplyconnectingCircuit protection 34WWindLGC 260Wintertime 97Wire ferrules 3

Pagina 287 - Open Close Buzzer

IDEC SmartRelay installation and wiring22 IDEC SmartRelay Manual2.1.2 Setup with different voltage classesRulesDigital modules can only be directly c

Pagina 288

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 23Overview: Connecting an additional expansion module to an expansion moduleWhen setting

Pagina 289 - IDEC SmartRelay Manual 275

IDEC SmartRelay installation and wiring24 IDEC SmartRelay Manual2.1.3 CompatibilityThe Text Display module can only be used with equipment series FL1

Pagina 290 - 8.3 Air-conditioning system

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 252.2 Installing/removing IDEC SmartRelayDimensionsThe IDEC SmartRelay installation dime

Pagina 291 - IDEC SmartRelay Manual 277

ii IDEC SmartRelay ManualQualified PersonnelThe device/system may only be set up and used in conjunction with this documentation. Commissioning and o

Pagina 292 - 278 IDEC SmartRelay Manual

IDEC SmartRelay installation and wiring26 IDEC SmartRelay Manual2.2.1 DIN rail mountingMountingHow to mount an IDEC SmartRelay base module and a digi

Pagina 293 - IDEC SmartRelay Manual 279

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 276. Using a screwdriver, push the interlock to the left. In its end position the slide

Pagina 294 - 280 IDEC SmartRelay Manual

IDEC SmartRelay installation and wiring28 IDEC SmartRelay ManualRemovalTo remove IDEC SmartRelay:... if you have installed only one IDEC SmartRel

Pagina 295 - 8.4 Factory door

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 292.2.2 Wall-mountingFor wall-mounting, first slide the mounting slides on the rear side

Pagina 296 - 8.4.2 Previous solution

IDEC SmartRelay installation and wiring30 IDEC SmartRelay Manual2.2.3 Mounting the Text DisplayTo prepare the mounting surface for the optional Text

Pagina 297 - IDEC SmartRelay Manual 283

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 31NoteThe number of supplied mounting screws and brackets on the FL1E-RD1 text display d

Pagina 298

IDEC SmartRelay installation and wiring32 IDEC SmartRelay Manual2.3 Wiring IDEC SmartRelayWire IDEC SmartRelay using a screwdriver with a 3-mm blade.

Pagina 299 - IDEC SmartRelay Manual 285

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 332.3.1 Connecting the power supplyIDEC SmartRelays (FL1E-*12RCC, FL1B-M08C2R2) are suit

Pagina 300 - 286 IDEC SmartRelay Manual

IDEC SmartRelay installation and wiring34 IDEC SmartRelay ManualCircuit protection with AC voltageTo suppress voltage peaks on the power supply lines

Pagina 301 - IDEC SmartRelay Manual 287

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 352.3.3 Connecting IDEC SmartRelay inputsRequirementsAt the inputs you connect sensor el

Pagina 302 - 288 IDEC SmartRelay Manual

PrefaceIDEC SmartRelay Manual iiiPrefaceDear customerWe thank you for purchasing IDEC SmartRelay and congratulate you on your decision. With IDEC Smar

Pagina 303 - 8.6 Luminous rows

IDEC SmartRelay installation and wiring36 IDEC SmartRelay ManualSensor connectionsConnecting glow lamps and 2-wire proximity switches (Bero) to FL1E-

Pagina 304 - 8.6.2 Previous solution

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 37Special features of FL1E-H12RCE/FL1E-B12RCE and FL1E-H12SNDFast inputs: I3, I4, I5 and

Pagina 305 - IDEC SmartRelay Manual 291

IDEC SmartRelay installation and wiring38 IDEC SmartRelay ManualWhen using a potentiometer and 10 V input voltage as the maximum value, you must ensu

Pagina 306 - 292 IDEC SmartRelay Manual

ML+L+MU1 I2 M2 U2I1 M1PEL+MMML+PE terminal for connecting earth and shielding the analog measuring cable Earth Cable shielding DIN railPERUN/STOPCu

Pagina 307 - 8.7 Service water pump

IDEC SmartRelay installation and wiring40 IDEC SmartRelay ManualInput Internal CircuitFL1E-H12RCC / FL1E-B12RCCFL1B-M08C2R2I1~I8N100nF390kΩ 180kΩ 270

Pagina 308 - 8.7.2 Previous solution

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 41FL1E-H12RCA / FL1E-B12RCAFL1B-M08D2R2I1~I84.3kΩ+5V510Ω150kΩ100nF100nFP2Internal Circui

Pagina 309 - I1 I2 I3

IDEC SmartRelay installation and wiring42 IDEC SmartRelay ManualFL1E-H12RCE / FL1E-B12RCE / FL1E-H12SNDFL1B-M08B2R2/FL1B-M08B1S2FL1E-H12RCE / FL1E-B1

Pagina 310 - 296 IDEC SmartRelay Manual

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 43FL1B-J2B2NoteFluctuating analog values are due to screening on the connecting wire fro

Pagina 311 - Technical data

IDEC SmartRelay installation and wiring44 IDEC SmartRelay Manual2.3.4 Connecting outputsFL1E-H12RCA / FL1E-B12RCA / FL1E-H12RCC / FL1E-B12RCC / FL1E-

Pagina 312

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 45Requirements for transistor outputsThe load connected to IDEC SmartRelay must have the

Pagina 313 - FL1E-H12RCC/FL1E-B12RCC

Prefaceiv IDEC SmartRelay ManualValid range of this manualThe manual applies to devices of series FL1E.New features of the FL1E IDEC SmartRelay devic

Pagina 314

V1, V2: 0 - 10 V DCV1, V2: 0 - 10 V DCR1: >= 5 kI1, I2: 0/4 - 20 mAR2: <= 250① Earth② DIN railFL1D-K2B2FL1D-K2BM2V1, V2: 0 - 10

Pagina 315

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 47Output Internal CircuitFL1E-H12RCA / FL1E-B12RCA / FL1E-H12RCC / FL1E-B12RCC / FL1E-H1

Pagina 316

IDEC SmartRelay installation and wiring48 IDEC SmartRelay ManualFL1D-K2BM2Analog Output (0/4 ... 20mA)22Ω10nF+14V(I1, I2)(M1, M2)InternalCircuitInte

Pagina 317

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 492.3.5 Connecting the AS interface busTo set the address of the module on the AS interf

Pagina 318

IDEC SmartRelay installation and wiring50 IDEC SmartRelay ManualLogic Assignments”n” depends on the plug–in position of the expansion module relative

Pagina 319

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 512.4 Putting into operation2.4.1 Switching on the IDEC SmartRelay/Power OnIDEC SmartRel

Pagina 320

IDEC SmartRelay installation and wiring52 IDEC SmartRelay ManualNotes for Using Expansion I/O Modules of Version 7 or earlierWhen using 3 or more exp

Pagina 321

>Program..Card..Setup..Start>Program..Card..Setup..Start2008-05-05 Mo 09:00>Program..Card..Setup..Start2002-01-31&B1Q12003-01-27Mo 09:00N

Pagina 322

IDEC SmartRelay installation and wiring54 IDEC SmartRelay Manual4. If you have enabled retentivity for at least one function, or a function is perman

Pagina 323 - FL1E-H12RCA/FL1E-B12RCA

IDEC SmartRelay installation and wiringIDEC SmartRelay Manual 55IDEC SmartRelay expansion modules, operating statesIDEC SmartRelay expansion modules h

Pagina 324

PrefaceIDEC SmartRelay Manual vAdditional differences compared to previous devices (FL1A to FL1D)• Extended set of reference parameters for function

Pagina 325

IDEC SmartRelay installation and wiring56 IDEC SmartRelay Manual

Pagina 326

IDEC SmartRelay Manual 573Programming IDEC SmartRelay Getting started with IDEC SmartRelayProgramming refers to creating a circuit program from the ID

Pagina 327

AI4 1 2 1 2 1 2 1 2L+ M I13I14I15 I16Q11Q9Q12Q10RUN/STOPL+ MAI5RUN/STOPL+ M AI3 I3 I4 I5 I6Q1 Q2 Q3 Q4AI

Pagina 328 - FL1E-B12RCE and FL1B-M08B2R2

Programming IDEC SmartRelay IDEC SmartRelay Manual 59IDEC SmartRelay’s connectorsThe term connector refers to all connections and states in IDEC Smart

Pagina 329

Programming IDEC SmartRelay 60 IDEC SmartRelay Manual3.2 Blocks and block numbersThis chapter shows you how to use IDEC SmartRelay elements to create

Pagina 330

Programming IDEC SmartRelay IDEC SmartRelay Manual 61Block representation on the IDEC SmartRelay displayThe figure below shows a typical view of the I

Pagina 331

Programming IDEC SmartRelay 62 IDEC SmartRelay ManualAdvantages of block numbersYou can connect almost any block to an input of the current block by

Pagina 332

Programming IDEC SmartRelay IDEC SmartRelay Manual 633.3 From circuit diagram to IDEC SmartRelay programView of a circuit diagramYou know, of course,

Pagina 333 - FL1D-K2B2, FL1D-K2BM2

Programming IDEC SmartRelay 64 IDEC SmartRelay ManualNoteAlthough you have four inputs available for logic operations (Basic functions, see Chapter 4

Pagina 334

Programming IDEC SmartRelay IDEC SmartRelay Manual 65Wiring exampleThe following figure shows you the wiring, based on a 230 V AC version of IDEC Smar

Pagina 335 - Determining the cycle time

Prefacevi IDEC SmartRelay Manual

Pagina 336 - Off =0000

Programming IDEC SmartRelay 66 IDEC SmartRelay Manual3.4 The four golden rules for operating IDEC SmartRelayRule 1Changing the operating mode• You cr

Pagina 337 - IDEC SmartRelay Manual 323

Programming IDEC SmartRelay IDEC SmartRelay Manual 67Rule 3Cursor and cursor movementThe following applies when you edit a circuit program:• You can m

Pagina 338

Programming IDEC SmartRelay 68 IDEC SmartRelay Manual3.5 Overview of IDEC SmartRelay menusProgramming modeParameter assignment modeParameter assignme

Pagina 339 - IDEC SmartRelay Manual 325

Programming IDEC SmartRelay IDEC SmartRelay Manual 693.6 Writing and starting the circuit programAfter you have designed a circuit, you want to write

Pagina 340 - 326 IDEC SmartRelay Manual

Programming IDEC SmartRelay 70 IDEC SmartRelay ManualMove the ”>” cursor to ”Edit Prg” (for editing the circuit program) and confirm with OK. IDEC

Pagina 341 - IDEC SmartRelay Manual 327

Programming IDEC SmartRelay IDEC SmartRelay Manual 71Circuit programS1 is connected to the I1 and S2 to the I2 input connector of the OR block.The cor

Pagina 342 - 328 IDEC SmartRelay Manual

Programming IDEC SmartRelay 72 IDEC SmartRelay Manual3.6.3 Circuit program inputLet us now write the circuit program, starting at the output and work

Pagina 343 - IDEC SmartRelay Manual 329

Programming IDEC SmartRelay IDEC SmartRelay Manual 73Now press or until the OR block appears on the display:1B1Q1The solid square cursor is still

Pagina 344 - 330 IDEC SmartRelay Manual

1Q1I1B1Programming IDEC SmartRelay 74 IDEC SmartRelay ManualNotePress to go the start of the Co list: I1, I2 ... to lo. Press to go to the end o

Pagina 345 - D.2 Text Display

Programming IDEC SmartRelay IDEC SmartRelay Manual 75We do not need the last two inputs of the OR block for this circuit program. You can mark the unu

Pagina 346 - 332 IDEC SmartRelay Manual

IDEC SmartRelay Manual viiContentsPreface... iiiContents ...

Pagina 347 - Type Numbers

Programming IDEC SmartRelay 76 IDEC SmartRelay ManualNext, press ESC.1B1Q1I2I31Q1I2B1I3xxI1I1Your circuit program layoutYou can review your first cir

Pagina 348 - Cable and Accessories Table B

Programming IDEC SmartRelay IDEC SmartRelay Manual 773.6.4 Assigning a circuit program nameYou can assign your circuit program a name that consists of

Pagina 349 - IDEC SmartRelay Manual 335

Programming IDEC SmartRelay 78 IDEC SmartRelay Manual3.6.5 PasswordYou can protect a circuit program from unauthorized access by assigning it a passw

Pagina 350 - 336 IDEC SmartRelay Manual

Programming IDEC SmartRelay IDEC SmartRelay Manual 79uppercase letters for the password, you can quickly access letters “at the end“ of the alphabet (

Pagina 351 - IDEC SmartRelay Manual 337

Programming IDEC SmartRelay 80 IDEC SmartRelay ManualChanging the password from the IDEC SmartRelay Base moduleYou must know the current password in

Pagina 352 - 338 IDEC SmartRelay Manual

Programming IDEC SmartRelay IDEC SmartRelay Manual 81The display shows:Old:ZZNew:Old:ZZNew:Clear the password by leaving the input box blank:3. Confir

Pagina 353 - IDEC SmartRelay Manual 339

Programming IDEC SmartRelay 82 IDEC SmartRelay Manual1. On the Text Display, press ESC to switch IDEC SmartRe-lay from RUN mode to STOP mode. Text Di

Pagina 354 - 340 IDEC SmartRelay Manual

Programming IDEC SmartRelay IDEC SmartRelay Manual 83NoteWhenever the Text Display is initialized, the password needs to be inputted again. The next t

Pagina 355 - IDEC SmartRelay Manual 341

Programming IDEC SmartRelay 84 IDEC SmartRelay Manual3.6.6 Switching IDEC SmartRelay to RUN modeIn the main menu, select RUN to start IDEC SmartRelay

Pagina 356 - 342 IDEC SmartRelay Manual

M:0.. 1234567891..01234567892..01234567ESC+CAI:7: 000008: 00000AQ:1: 000002: 01000Analog inputs AI7 to AI8Analog outputs AQ1 to AQ2Memory Markers M1 t

Comentarios a estos manuales

Sin comentarios